MG-600WX微機消諧裝置江蘇mg-600wx 要多少錢 三達微機消諧裝置 mg-600wx 三達電子10年專業(yè)生產(chǎn)MG-600WX微機消諧裝置以高可靠的工業(yè)標準設(shè)計而成,采用多種隔離和抗干擾措施,能夠在高干擾電力系統(tǒng)環(huán)境中可靠運行。 MG-600WX 微機消諧裝置是我公司針對電力部門和用戶由于鐵磁消諧而時常發(fā)生的電壓互感器(PT)燒毀甚至爆炸的惡性事故,而研制開發(fā)的一種智能消諧裝置。本裝置利用ARM處理器作為裝置的核心處理元件,裝置具有性能穩(wěn)定,抗干擾能力強等優(yōu)點。不但可以消除鐵磁諧振,還可以對過電壓,單相接地作出報警指示。
功能及特點 適用于配電網(wǎng)各種電壓等級。 迅速消除三分頻、二分頻、工頻以及三倍頻等特征頻率的鐵磁諧振。 能區(qū)分外部過電壓、鐵磁諧振和單相接地。 采用大功率、無觸點消諧元件,消諧迅速、可靠。 提供一組無源報警節(jié)點。 故障發(fā)生時,能顯示故障報告(類型、時間、電壓值和頻率)。 選配的微型打印機可以及時打印故障報告。 可配置通信接口將相關(guān)信息傳給上級監(jiān)控系統(tǒng)。 保存十條最近發(fā)生的故障信息,失電后數(shù)據(jù)不丟失。 具備看門狗防止死機現(xiàn)象發(fā)生。 具有完善的自檢功能。 人機接口操作簡單方便,全中文菜單,顯示信息豐富直觀。
產(chǎn)品負責人:余經(jīng)理(13874194348)聯(lián)系電話: 圖文傳真:在線QQ:1564610977 2251986823地址:湖南省、株洲市、醴陵市(五里墩經(jīng)濟開發(fā)區(qū))、醴陵工商總局對面了解更多信息進入三達電子官網(wǎng) http://www.sandadz.com
以下型號三達電子均可為您提供一流的服務(wù),一流的質(zhì)量,咨詢可直接來電400-669-1718.cx-wxq,qdsc-2300a,zb-lxq,hh-kx196hz,xd-tzx-200hh-kx196h,ky-wx300,hy-xx,ds-ksx196h,hyt-ksx196txk-3500,ksx196-ha,sh-wx-y-m-2p,cxrd-wxz-a1,sc-dtxlch-wxyh,nr-tzx-200,mg-600wx,gsy-xx-1-t,gkwx100agkwx100c,gyxx-i-10,tld-wxyh,hyr-4a,hyr-3a,xd-tzx-100
三達電子阿里巴巴誠信通中心:sandayibiao.1688.com 阿里企業(yè)官網(wǎng):www.zzsanda.com.湖南省著名商標企業(yè)——歡迎您在線采購所需產(chǎn)品。
三達電子——湖南MG-600WX微機消諧裝置廠家,10年老品牌,用心服務(wù)于成套電氣廠及各應(yīng)用領(lǐng)域.湖南三達電子專業(yè)生產(chǎn)MG-600WX微機消諧裝置廠家,數(shù)百款湖南MG-600WX微機消諧裝置為您量身定制,銷售熱線:400-669-1718
ZTE launches PowerMaster ONE solutions
During the exhibition, ZTE energy solutions expert Huang Yuanhua published "Green & Magic Energy Box, ZTE New Generation Hybrid Solution-PowerMaster ONE keynote speech, the development trend of power supply based on hybrid communication energy, focusing on PowerMaster ONE scheme in solving the problem of the lack of electricity supply site area, through innovative design concepts and technologies to help clients achieve the maximum value of interest, especially in the background of telecom operators gradually sell assets to PASSIVE infrastructure operators, PowerMaster ONE scheme can meet the site from a single user power supply to the power supply smooth expansion and upgrading, effectively avoid the unique advantage of customers' investment losses.中興ZXDU58 W600 V4.5R01M01室外壁掛式電源柜
ZTE energy solutions expert Li Weibo published on the theme of "An Innovative Energy Management the System for Telecom Energy Network", showing the energy management scheme for iEnergy networks based on cloud technology, presents ZTE energy products in the field of network energy management中興ZXDU58 W600 V4.5R01M01室外壁掛式電源柜rgy industry, ZTE is continuously innovating in the energy field, and is committed to continuously introducing products and programs that satisfy customers. There are many market application cases in the world.
“蓄電池備電+移動油機應(yīng)急發(fā)電”是有市電區(qū)域最基本的基站后備動力保障配置方案。對于頻繁需要上站應(yīng)急發(fā)電的基站疊加小功率太陽能系統(tǒng),可大幅降低應(yīng)急發(fā)電成本,并持續(xù)獲得電費節(jié)省,投資回報周期小于3年。傳統(tǒng)疊光方案存在太陽能利用不充分、影響電池充電管理等問題,采用兼容太陽能輸入的開關(guān)電源系統(tǒng)疊光,可以低成本實現(xiàn)高收益。支持疊光的
通信電源系統(tǒng)有利于在運維期間動態(tài)調(diào)整配置,針對應(yīng)急發(fā)電上站次數(shù)較多的基站實施疊光,能最小化疊光投資,在提高動力保障的同時長期節(jié)省電費和應(yīng)急發(fā)電成本。
一、電池和應(yīng)急發(fā)電問題多,成為斷站因素
隨著互聯(lián)網(wǎng)快速發(fā)展,人們生活已經(jīng)離不開網(wǎng)絡(luò),需要無處不在的移動寬帶;痉(wěn)定運行是通信網(wǎng)絡(luò)高可用的基礎(chǔ),由于停電不可避免,基站需要有合理的后備動力保障方案。蓄電池+移動油機是最常用的后備動力保障方式,停電時由蓄電池支持基站工作,當蓄電池容量不足時,調(diào)派移動油機上站發(fā)電,保障基站運行不中斷。
由于居民對噪聲的普遍反對,以及站點所在建筑物出入管理原因,實際上城市站點很難上站應(yīng)急發(fā)電;農(nóng)村站點發(fā)電距離遠、高山站上站困難,應(yīng)急發(fā)電保障度困難。通過對基站通信中斷原因分析,平均57%網(wǎng)絡(luò)中斷與基站配套相關(guān),停電是引起網(wǎng)絡(luò)中斷的要因。
以某市某運營商3453個站點為例,高山站無法應(yīng)急發(fā)電的有195個,業(yè)主原因經(jīng)常無法上站發(fā)電的有2004個,無法用移動油機保障的站點占比高達64%。該運營商單月停電2771站次,由于停電原因發(fā)生斷站1923次,停電斷站率高達69%。停電斷站涉及1322站點,平均每站斷站時長高達2.1小時。應(yīng)急發(fā)電次數(shù)802次,停電發(fā)電比例29%,其中包括40次應(yīng)急發(fā)電不及時導致基站運行中斷。由此可見,停電后不能應(yīng)急發(fā)電或應(yīng)急發(fā)電不及時是造成通信網(wǎng)絡(luò)中斷的因素。
二、蓄電池+移動油機,后備動力保障成本很高
在基站容量一定的條件下,蓄電池容量取決于后備時長要求,后備時長必須大于應(yīng)急發(fā)電上站時間,并留有足夠的余量。對于頻繁停電的基站,如果具備小型固定油機安裝條件,可安裝固定油機,不具備固定油機安裝條件的基站,適當增配電池,如郊縣、農(nóng)村、山區(qū)備電時長可分別增至5、7、10小時。對于通信負載平均功率為2kW的站點,備電7小時需要配置一組500Ah蓄電池,電池成本很高。移動油機作為應(yīng)急保障電源,停電時安排發(fā)電人員上站發(fā)電,即使應(yīng)急發(fā)電人員尚未到達站點時市電已恢復,也需要支付應(yīng)急發(fā)電費用。
應(yīng)急發(fā)電成本包括上站人工費用、發(fā)電油費、移動油機攤銷成本。上站人工費用與當?shù)貏趧恿Τ杀鞠嚓P(guān),一般在300元/次左右;發(fā)電燃油成本與發(fā)電時長、耗油率相關(guān),一般平均每次發(fā)電消耗50元左右燃油;移動油機攤銷成本包括油機折舊、油機維護成本分攤,平均每次發(fā)電分攤30元左右。農(nóng)村站點是停電高發(fā)區(qū)域,平均月上站次數(shù)可能超過一次,按應(yīng)急發(fā)電成本每次380元計,如果每月發(fā)電一次,每年單站應(yīng)急發(fā)電成本4560元,發(fā)電成本很高。
減少停電斷站、提高通信網(wǎng)絡(luò)質(zhì)量是通信動力系統(tǒng)建設(shè)與維護的要務(wù)。不論是增配蓄電池延長備電時長、提高應(yīng)急上站發(fā)電次數(shù)、安裝固定油機等,都可以降低停電斷站率,提高通信網(wǎng)絡(luò)質(zhì)量。由于蓄電池成本很高,增加1小時備電時長平均每站每年需要投入400元左右;每增加1次應(yīng)急上站發(fā)電需增加380元左右;安裝固定油機一次性投入成本很高。不論是電信運營商還是鐵塔運營商,都需要有以較低成本提高保障質(zhì)量的解決方案。
三、站點疊光,低成本提高供電質(zhì)量、降低運維成本中興ZXDU58 W600 V4.5R01M01室外壁掛式電源柜
站點疊光方案,指在站點電源基礎(chǔ)上疊加太陽能,安裝僅滿足通信負載功率需求的太陽能電池板,優(yōu)先使用太陽能供電的方案。太陽能是可再生能源典型代表,疊加太陽能可降低站點電費。例如,對于平均直流負載功率為2kW的站點,假設(shè)日照時數(shù)為4小時(全國省會城市貴陽最低2.84小時、拉薩最高6.7小時,一半以上超過4小時),采用疊光方案可年省電2920度,需要安裝約2.5kWp的太陽能電池板?蛻舨少徧柲茈姵匕濉⑻柲苣K及其安裝服務(wù)成本為22000元,如果電價為1元/度,則疊光方案的投資回報周期為7.5年左右,決策投資相對困難。
疊光后,如果基站停電發(fā)生在有日照的時段,可以不需要應(yīng)急發(fā)電。由于深夜通信業(yè)務(wù)較少、夜晚上站發(fā)電相對危險等因素,實際很少夜間發(fā)電。此外,由于移動油機普遍不防雨且室內(nèi)發(fā)電危險,雨天一般也不發(fā)電。因此,應(yīng)急發(fā)電多在沒有下雨的白天進行,該時間段太陽能可用概率很高,即使陰天太陽能發(fā)電量很少,也可延長電池備電時長。經(jīng)過測算,采用疊光方案的站點,可以減少80%以上上站應(yīng)急發(fā)電成本,并降低由于應(yīng)急發(fā)電不及時帶來的斷站風險。
例如,某市某運營商共432個基站,2014年12月份發(fā)電77次,只有一次為夜間發(fā)電,發(fā)電次數(shù)TOP 10基站平均發(fā)電15.64小時,平均發(fā)電次數(shù)3.8次,最長一次發(fā)電時長僅5.42小時,發(fā)電時長相對平均。在相同應(yīng)急保障條件下,對于應(yīng)急發(fā)電TOP 10站點具備安裝太陽能電池板條件的,可采用疊光措施,假定減少應(yīng)急發(fā)電次數(shù)比例為80%,單站一個月可以節(jié)省上站費用1155元。由于12月份并非停電高峰,評估單站一年可節(jié)省1.4萬元以上發(fā)電費用,遠比省電價值更大,投資回報周期僅1.3年左右。如果批量采用疊光方案,還可能獲得國家和地方政府財政補貼,如浙江省對于太陽能發(fā)電量每度補貼0.42元,可以進一步降低投資回報周期。由于應(yīng)急發(fā)電成本以人工費用為主,人工費用呈長期上升趨勢,隨著應(yīng)用時間的增加,疊光方案回報越來越高。
3~5年是合理的投資回報周期,按示例,疊光方案總投資2.2萬元,只要每年節(jié)省超過4400元,就值得投資。一個2kW站點年省電按2920元計,只需要能年節(jié)省1480元應(yīng)急發(fā)電費用即可滿足5年投資回報要求。按每次發(fā)電成本380元計,對于年上站應(yīng)急發(fā)電需求4次以上的站點,都值得投資疊光方案。如果太陽能發(fā)電可獲得補貼,如0.42元/度,每年補貼1226元,加之站點都或多或少存在應(yīng)急發(fā)電需求,對所有具備安裝太陽能條件的站點普遍疊光,會具備非常好的投資回報。一個單運營商2G/4G站點或兩個運營商單制式共享站典型負載平均功率接近2kW,可配置一個3kW太陽能模塊和9×250Wp太陽能電池板,只需要凈占地面積13平米。當安裝面積不足時,可以欠配安裝,如只安裝1.5kW太陽能電池板,停電時不足的功率由電池補充,使原來只能備電3小時的站點(300Ah電池)在陽光較好時備電時長延長至12小時以上,同樣能大幅減少應(yīng)急發(fā)電次數(shù)。
四、傳統(tǒng)疊光方案,電池管理風險需要謹慎控制
傳統(tǒng)疊光方案指在站點內(nèi)增加一套獨立的太陽能系統(tǒng),太陽能模塊輸出的直流電直接與存量開關(guān)電源直流輸出并聯(lián),太陽能系統(tǒng)與開關(guān)電源互相獨立。由于需要優(yōu)先使用太陽能,太陽能系統(tǒng)輸出的開路電壓應(yīng)高于開關(guān)電源。對于傳統(tǒng)疊光方案來說,太陽能系統(tǒng)輸出電壓設(shè)置非常關(guān)鍵,不合適的設(shè)置會導致部分甚至全部太陽能被浪費。當開關(guān)電源或太陽能系統(tǒng)電壓測量電路出現(xiàn)偏差時,也可能發(fā)生同樣的結(jié)果。此外,開關(guān)電源均充時,由于電源輸出電壓更高,這段時間內(nèi)太陽能無法被利用。
開關(guān)電源具備蓄電池管理功能,能限制最大充電電流以保護蓄電池使用壽命。當太陽能系統(tǒng)輸出電壓高于設(shè)置值時,過高的電壓使電池過充。由于疊加的太陽能功率大于負載功率是常態(tài),在蓄電池需要充電時,多余的太陽能功率也會對電池進行充電,使電池充電電流大于開關(guān)電源設(shè)定的充電限流值,蓄電池實際充電電流與開關(guān)電源系統(tǒng)測量值不一致,不利于蓄電池充電管理。
開關(guān)電源都有溫度補償功能,電池溫度補償范圍為±2V,由于開關(guān)電源溫度補償功能無法與太陽能系統(tǒng)關(guān)聯(lián),溫度降低時電源浮充電壓升高,導致太陽能浪費,而溫度升高時太陽能輸出電壓不變,使電池加速充電失水。如果取消開關(guān)電源溫度補償功能,太陽能可以得到充分應(yīng)用,但會影響蓄電池使用壽命。
為了充分利用太陽能,保護電池壽命,對于傳統(tǒng)疊光方案需要準確配置太陽能電池板數(shù)量,謹慎設(shè)置太陽能系統(tǒng)和開關(guān)電源電壓,并取消電池溫度補償功能,在溫度變化不大的室內(nèi)站點使用。
五、電源兼容太陽能,消除電池管理風險
隨著電力電子技術(shù)與數(shù)字信息技術(shù)融合發(fā)展,電源模塊控制芯片內(nèi)含軟件和算法,使硬件功能可由軟件定義,稱為軟電源(SDP,Software Defined Power),可以很方便地實現(xiàn)不同功能模塊兼容。太陽能模塊與整流模塊兼容就是典型的軟電源特性,采用兼容太陽能的開關(guān)電源系統(tǒng),就能在任何合適的站點在電源模塊位置插入太陽能模塊,不需要采購獨立的太陽能控制系統(tǒng),除了太陽能電池板采購及安裝費用外,只需要從開關(guān)電源廠家購買一個太陽能模塊即可。
由于太陽能模塊與整流模塊兼容,通過同一個監(jiān)控模塊控制,不論太陽能功率大小,也不論蓄電池需求電壓高或低,都會優(yōu)先調(diào)度使用太陽能,使太陽能全部得到利用。太陽能模塊和整流模塊的輸出電壓統(tǒng)一控制,并與中興ZXDU58 W600 V4.5R01M01室外壁掛式電源柜電池溫度補償同步,蓄電池充放電管理功能完全不受影響。山西鐵塔聯(lián)合華為試點MTS站點電源疊光,疊光工程量就是安裝太陽能電池板的工作量,系統(tǒng)不需要調(diào)試就成功投產(chǎn)。因此,部署站點時宜優(yōu)選支持疊光功能的電源系統(tǒng),引導全行業(yè)電源向多功能兼容方向發(fā)展。對于存量宜疊光站點,如果存量電源不是高效電源且無法直接替換高效模塊,優(yōu)先采用多功能高效電源改造。
六、應(yīng)急發(fā)電TOP N管理,實現(xiàn)低成本疊光
由于站點規(guī)劃建設(shè)時很難預(yù)測未來應(yīng)急發(fā)電情況,對于投產(chǎn)后的站點可以采用基于短板改進的應(yīng)急發(fā)電次數(shù)TOP N管理手段,通過站點網(wǎng)管系統(tǒng)對應(yīng)急發(fā)電次數(shù)進行統(tǒng)計,選擇應(yīng)急發(fā)電次數(shù)多、合適安裝太陽能電池板的站點進行疊光,可以實現(xiàn)精準配置,最小化疊光成本。如山西試點的疊光站點就是停電次數(shù)較多的站點,經(jīng)測算,站點疊光年收益高達2.1萬元/年,非?捎^。
如果全面采用支持疊光的電源系統(tǒng),定期對區(qū)域內(nèi)基站應(yīng)急發(fā)電次數(shù)TOP N站點進行疊光、疊油(不具備安裝太陽能條件,但可安裝固定油機的)、疊電(對于不能疊光、疊油的站點,可直接增配新電池或鋰電池)等手段優(yōu)化,逐漸消滅需要頻繁應(yīng)急發(fā)電的站點,大幅度減少應(yīng)急發(fā)電上站次數(shù),降低應(yīng)急發(fā)電成本,并在節(jié)能的同時提高基站可靠性。到目前為止,疊光是以較低成本實現(xiàn)站點供電高保障的首選方案。
"Battery preparation +
mobile oil engine emergency power generation" is the most basic backup power support configuration of base station in the city. For the base stations that frequently need to go to the station for emergency power generation, the small power solar system can be superimposed, and the cost of emergency power generation can be greatly reduced, and the electricity cost will be continuously saved. The investment return cycle is less than 3 years. Traditional stacking scheme has many problems, such as inadequate solar energy utilization and influence on battery charging management. The switching power supply system compatible with solar input can achieve high cost at low cost. The communication power supply system supporting stacking light is conducive to dynamically adjusting the configuration during operation and maintenance. It can reduce the cost of light investment for the base stations which are more frequent on the basis of emergency power generation, and minimize power overlay investment. At the same time, it can save electricity and emergency power generation cost at the same time.
One, battery and emergency power generation problem, become the first factor of fault station
With the rapid development of the Internet, people can not live without the network, and it needs ubiquitous mobile broadband. The stable operation of the base station is the foundation of the high availability of the communication network. Because of the inevitable blackout, the base station needs a reasonable backup power support scheme. Battery + mobile oil machine is the most commonly used backup power support mode. When the power fails, the battery will support the base station. When the battery capacity is insufficient, the mobile oil station will be dispatched to the station to generate electricity, so that the base station will run without interruption.
Because of the widespread opposition to noise and the reasons for the access and management of buildings in the site, it is very difficult for the urban station to go to the station for emergency power generation. The rural station is far away from the power station, and the station on the high m中興ZXDU58 W600 V4.5R01M01室外壁掛式電源柜ountain station is difficult, and the emergency generation support is difficult. Through the analysis of the reason for the interruption of the base station communication, the average 57% network interruption is related to the base station, and the blackout is the first cause of the network interruption.
Take 3453 operators of a certain city as an example, there are 195 stations that can't generate electricity by emergency at Gaoshan station, and 2004 of them cannot afford to go to station because of owners' reasons. The proportion of stations that cannot be protected by mobile oil machine is 64%. The operator single month outage 2771 times, due to power outages cause broken station 1923 times, power station fault rate is as high as 69%. The blackout station involves 1322 stations, and the average height of each station is up to 2.1 hours. Emergency power generation 802 times, power generation ratio of 29%, including 40 emergency power generation is not timely lead to the base station operation interruption. So it can be seen that the failure of emergency power generation or emergency power generation after blackout is the first factor that causes the interruption of the communication network.
Two. Battery + mobile oil machine, the cost of backup power is very high
Under the condition of certain capacity of the base station, the capacity of the battery depends on the reserve time requirement, and the reserve time must be larger than the emergency power generation time, leaving enough margin. The base station for the frequent power outages, if you have a small fixed oil machine installation conditions, can be installed and fixed oil machine, do not have the conditions of fixed base station installation of machine oil, properly equipped with batteries, such as suburban, rural and mountainous areas by time can be increased to 5, 7, 10 hours. For a station with an average power of 2kW for the communication load, a set of 500Ah batteries should be configured for 7 hours, and the cost of the battery is very high. The mobile oil as an emergency power supply, when the power is cut off, the generator will be sent to the station to generate electricity. Even if the emergency generator has not arrived at the site, the electricity has been recovered, and the emergency power generation cost should be paid.
The cost of emergency power generation includes the labor cost of the station, the cost of power generation oil, and the amortization cost of the mobile oil machine. On labor costs associated with local labor costs, generally about 300 yuan / times; the cost of fuel and power generation time, fuel consumption rate, the average power consumption per 50 yuan fuel; mobile oil machine including machine depreciation, amortization cost of oil and oil machine maintenance costs, the average power allocation of 30 yuan. The rural station is a high power failure area. The number of stations on average may exceed one time per month. According to the emergency power generation cost, 380 yuan per time. If the electricity is generated once a month, the annual single station emergency power generation cost is 4560 yuan, and the cost of generating electricity is very high.
中興ZXDU58 W600 V4.5R01M01室外壁掛式電源柜the high cost of battery, the increase of 1 hours, the average power consumption time is about 400 yuan per station per year. For every 1 increase, the power generation for emergency stations needs to increase by about 380 yuan, and the cost of installing fixed oil units is high. Both telecom operators and tower operators need solutions to improve the quality of the guarantee at a lower cost.
Three, site stacking, low cost to improve the quality of power supply and reduce operation and maintenance costs
The site overlay scheme refers to the solar panels that are installed on the site power supply and only meet the power demand of communication load. Solar energy is a typical representative of renewable energy, and the superposition of solar energy can reduce the electricity cost of the site. For example, the average DC load power for the 2kW site, assuming the sunshine hours for 4 hours (the capital city of Guiyang, Lhasa's highest minimum 2.84 hours 6.7 hours, more than half of more than 4 hours), the scheme can stack light annual saving 2920, need to install about 2.5kWp solar panel. The cost of customer purchasing solar panels, solar modules and installation services is 22000 yuan. If the electricity price is 1 yuan / degree, the investment return period of the scheme is about 7.5 years, making investment decisions relatively difficult.
After stack light, if the base station blackout occurs in the period of sunshine, there is no need for emergency power generation. Because of the low night communication service, the night is on the station。
數(shù)據(jù)中心是我國實施“互聯(lián)網(wǎng)+”的重要基礎(chǔ)設(shè)施載體。相關(guān)統(tǒng)計顯示,截至2014年年底全國共規(guī)劃建設(shè)數(shù)據(jù)中心310個,已投入使用230個,其中約有三分之一為大型數(shù)據(jù)中心。另據(jù)數(shù)據(jù)中心產(chǎn)業(yè)聯(lián)盟發(fā)布的《數(shù)據(jù)中心產(chǎn)業(yè)發(fā)展白皮書》顯示,2011~2016年我國數(shù)據(jù)中心總投資將超過1萬億元。其中高低壓供配電、不間斷電源、制冷系統(tǒng)等配套設(shè)施造價在基礎(chǔ)設(shè)施造價中所占比例約75%~80%。
大型數(shù)據(jù)中心建設(shè)熱潮來襲。然而,在大型數(shù)據(jù)中心的運營中,巨大的配電成本支出正在對運營商形成挑戰(zhàn),同時配電單元往往占用大量面積,不利于數(shù)據(jù)中心的節(jié)能環(huán)保。因此,如何能夠在保證數(shù)據(jù)中心穩(wěn)定運行的情況下,實現(xiàn)配電系統(tǒng)的革新,顯著降低配電成本成為業(yè)界關(guān)注的問題。正是在這一趨勢下,中壓型UPS開始興起。中壓型UPS能夠提高接近負荷中心的電壓等級,減少低壓配電環(huán)節(jié),降低能耗?梢灶A(yù)見,隨著電信行業(yè)去電信化、減配增效的深入推進,中壓UP中興ZXDU58 W600 V4.5R01M01室外壁掛式電源柜S系統(tǒng)將迎來廣闊的市場前景。
大型數(shù)據(jù)中心低壓配電系統(tǒng)亟待革新
我國早期通信系統(tǒng)負有政治安全責任,通信網(wǎng)絡(luò)一旦中斷將追究相關(guān)方政治責任,所以我國通信系統(tǒng)中冗余配置較高,這從早期UPS和開關(guān)電源蓄電池組后備時間的不一致可見一斑。所以,在建設(shè)數(shù)據(jù)中心的供電系統(tǒng)時,為了保證系統(tǒng)安全可靠性,充分考慮設(shè)備配置和冗余。
目前大型數(shù)據(jù)中心園區(qū)或大型數(shù)據(jù)中心的供配電結(jié)構(gòu)一般是引市電高壓(110kV)或中壓(35kV、10kV)到高壓配電室然后再分配給干式變壓器(轉(zhuǎn)成380V)并配置成套低壓配電系統(tǒng),成套低壓配電系統(tǒng)中的饋電柜再通過密集母線或電纜分配電能到每個樓層的低壓配電柜,再分配到大型的UPS(如500kVA、600kVA),目前每套低壓配電系統(tǒng)一般最大配置到2000kVA,每套低壓系統(tǒng)最多帶兩套大容量的1+1型UPS系統(tǒng)或2N型UPS系統(tǒng),這種從高壓配電系統(tǒng)-低壓配電系統(tǒng)-UPS的結(jié)構(gòu)在早期中小型數(shù)據(jù)中心應(yīng)用廣泛,但隨著數(shù)據(jù)中心單UPS系統(tǒng)配電容量的加大,這種配電結(jié)構(gòu)存在諸多缺陷。
,投資浪費嚴重。單套低壓配電系統(tǒng)存在浪費投資、浪費機房空間、浪費密集母線等浪費現(xiàn)象。雖然也可以將變壓器配置在每個樓層,但是供配電結(jié)構(gòu)沒有變化,隨著大型UPS的使用,每套2000kVA的低壓配電系統(tǒng)下掛2套600kVA(1+1)考慮充電電流及負載冗余后即滿。
第二,增加供配電等級,增加了安全隱患。在相同的電源器件環(huán)境中,對于配電系統(tǒng)來說上下游開關(guān)越少越安全,配電等級越少可靠性越高,接近負荷中心的電壓等級越高越節(jié)能。大型數(shù)據(jù)中心園區(qū)35kV開關(guān)站-10kV高壓配電柜-10kV配電柜-變壓器-低壓配電柜-密集母線-樓層配電柜-UPS系統(tǒng),8層級的配電結(jié)構(gòu),每多1個層級則意味著增加一個故障隱患點。
第三,影響機房可使用面積,增加建筑成本。對于大型數(shù)據(jù)中心,如果每層樓均配置變壓器低壓配電室、UPS系統(tǒng)電源室,相應(yīng)電源區(qū)域要預(yù)留40%以上的空間,對于通信機房來說,一般預(yù)留25%~30%空間,且低壓配電結(jié)構(gòu)冗余度越大占機房面積越大。
中壓型一體化UPS正在興起
回顧通信領(lǐng)域的高低壓配電發(fā)展趨勢,交流系統(tǒng)從早期的380V到中興ZXDU58 W600 V4.5R01M01室外壁掛式電源柜10kV,不間斷電源從220V到240V、336V高壓直流,設(shè)備功耗密集程度越大配電系統(tǒng)的電壓等級也隨之上升,采用高壓等級的設(shè)備可以更多地減少線損、線纜母線投資、節(jié)省設(shè)備占地面積、減少轉(zhuǎn)換次數(shù)也意味著節(jié)能,同樣,改變傳統(tǒng)的380V進380V出220V配電的結(jié)構(gòu),提高UPS進入電壓等級至10kV以上也具備以上優(yōu)點。使用如10kV的UPS的前提是將傳統(tǒng)低壓配點系統(tǒng)的計量功能、功率補償功能、低壓發(fā)電機組轉(zhuǎn)移到10kV系統(tǒng)。
低壓配電中的計量可采用高壓端計量。傳統(tǒng)數(shù)據(jù)中心往往是通過在低壓段低壓配電系統(tǒng)中配置計量柜的方式,但是隨著數(shù)據(jù)中心規(guī)模越來越大,大型數(shù)據(jù)中心已有10套以上的低壓配電系統(tǒng),且分為生活用電、辦公用電等,統(tǒng)計量工作放在高壓將成為一種趨勢。采用高壓端計量的同時仍可以通過中壓型一體化UPS的變壓器的數(shù)據(jù)采集進行自動統(tǒng)計上報。
低壓配電中的補償功能可改為高壓補償和負荷中心就近補償。對于數(shù)據(jù)中心來說,感性負載和容性負載同時存在,感性負載主要為空調(diào)主機、風機等電機類設(shè)備;整流設(shè)備、IT設(shè)備為容性負載;也就說數(shù)據(jù)中心感性負載和容性負載是同時存在的,是相互補充的。統(tǒng)計顯示,目前大部分通信局樓的低壓電容器柜多設(shè)置為人工投入,因為由于感性負載和容性負載的同時存在,功率因數(shù)cosΦ通常都在0.92以上。采取在低壓配電系統(tǒng)進行補償屬于后補償,沒有起到有效作用,且在諧波環(huán)境下容易引發(fā)電容器共振并存在爆炸風險。因此未來的數(shù)據(jù)中心應(yīng)針對具體機房環(huán)境測試其諧波和無功負荷情況進行就近補償。
大型數(shù)據(jù)中心采用高壓油機是必然趨勢。目前大型、超大型數(shù)據(jù)中心已推廣采用高壓油機,帶來很多優(yōu)勢:電纜、上下游開關(guān)配置方面,簡化了配電結(jié)構(gòu),高壓油機使用高壓電纜傳輸電力,高壓輸電電流相當于低壓輸電電流的二十六分之一,上下游開關(guān)及電纜投資節(jié)省、敷設(shè)及施工方便、線損很小、安全性也較高;便于進行多機并機,形成大容量后備電源,消除了常壓油機系統(tǒng)面臨的輸出容量瓶頸;若采用高壓空調(diào)必須采用高壓油機,離心機組啟動電流較大,如國內(nèi)某運營商集團企業(yè)標準規(guī)定“除變頻供電的電動機外,單臺額定功率大于350kW 的電動機,宜采用10kV 電源供電”。采用高壓冷水機組供電后,可以相應(yīng)減少變壓器及低配和密集母線、電纜的投資,綜合對比高壓冷水機組的價格因素,初步統(tǒng)計可以節(jié)省0.075萬元/kW(制冷量);高壓油機集中布置,可以根據(jù)園區(qū)功耗發(fā)展情況分期、逐臺投資,而低壓油機則只能是與低配模塊化相匹配而無論油機的實際負載率,造成油機投資浪費;推廣使用高壓油機之后低壓配電系統(tǒng)中的ATS柜可以減配。
以上分析證明,低壓配電系統(tǒng)中的主要功能,計量、電容、ATS柜等都可以代替,實施高壓到負荷中心的二級轉(zhuǎn)換比再經(jīng)過低壓側(cè)顯然可以節(jié)省更多成本,減少中間配電環(huán)節(jié)后也使得可靠性提高很多。
國外中壓UPS系統(tǒng)應(yīng)用現(xiàn)狀
從歐洲地區(qū)的中壓UPS系統(tǒng)發(fā)展來看,中壓UPS系統(tǒng)多應(yīng)用在工業(yè)級不間斷電源應(yīng)用場景中,擁有兆瓦級額定功率和高達99.5%的中壓UPS,儲能和逆變器依然處于低壓水平,它還能大幅簡化維護作業(yè)和降低系統(tǒng)成本。中壓UPS可進行改造,進行定制化設(shè)計,可兼容各種各樣的儲能裝置,具體取決于所需的保護時間。超級電容器和飛輪可在幾秒鐘內(nèi)提供高密度保護,而電池可以達到長達15分鐘的備用時間。
北美地區(qū)早期工業(yè)用中壓型UPS系統(tǒng)多為集裝箱式結(jié)構(gòu)或露天箱體結(jié)構(gòu)。數(shù)據(jù)中心使用的中壓型UPS系統(tǒng)多為戶內(nèi)型、模塊化結(jié)構(gòu),容量為2.0MW~20MW。包括輸入輸出開關(guān)柜、變壓器箱、主控單元、PES柜(中壓)、雙向變流器、儲能箱等。戶外型儲能箱后備時間為1~3分鐘,戶內(nèi)型后備時間根據(jù)客戶需求配置,可以達到30分鐘以上。
可以看到,國外已有類似產(chǎn)品,但是國外的中壓UPS較多定位于將UPS系統(tǒng)功能集中于中壓段解決,目前已在美國的部分大型數(shù)據(jù)中心開始應(yīng)用。
尤為值得一提的是,相比傳統(tǒng)低壓UPS,中低壓一體化UPS在同樣的場景下將減少80%的投資成本,而之所以能夠帶來這一“不可思議”的改變,則主要得益于大幅減少了傳統(tǒng)低壓配電柜的占地面積,節(jié)省了大量的低壓配電母線、電纜,同時發(fā)電機組采用高壓油機也便于分期投資?梢灶A(yù)見,中壓UPS系統(tǒng)的建設(shè)將為運營商節(jié)省大量的供配電成本,進一步提升運營商的市場競爭力。
The data center is the implementation of the "critical infrastructure support Internet plus" in china. Statistics show that as of the end of 2014, 310 data centers were planned and built in China, and 230 of them had been put into operation, of which about 1/3 were large data centers. According to the data center industrial development white paper published by the data center industry alliance, the total investment of China's data center will exceed 1 trillion yuan in 2011~2016. The cost of high and low voltage supply and distribution, uninterrupted power supply, refrigeration system and other supporting facilities is about 75%~80% in the cost of infrastructure.
Large data center construction upsurge is coming. However, in the operation of large data centers, the huge distribution cost is challenging the operators. At the same time, the distribution units often occupy a large number of areas, which is not conducive to the energy saving and environmental protection of data centers. Therefore, how to ensure the stable operation of data center and realize the innovation of distribution system, significantly reduce the distribution cost has become the industry's concern. It is under this trend that medium voltage UPS is beginning to rise. The medium voltage UPS can improve the voltage level near the load center, reduce the low voltage distribution link and reduce the energy consumption. It is foreseeable that the medium voltage UPS system will usher in a broad market prospect as the telecom industry goes to the telecommunication industry, the reduction and the increase of efficiency.
The low voltage distribution system in large data center needs to be innovated urgently
China's early communication system bears the responsibility of political security. Once the interruption of communication network is concerned, the related party's political responsibilities will be investigated. So the redundancy allocation in China's communication system is relatively high, which is evident from the inconsistency between the early UPS and the reserve time of the switching power battery group. Therefore, in building the power supply system of the data center, in order to ensure the safety and reliability of the system, the configuration and redundancy of the equipment are fully considered.
The current power supply structure of large data center park or large data center is generally cited city electric pressure (110kV) or medium (35kV, 10kV) to the high voltage distribution room and then assigned to the dry-type transformer (to 380V) and the configuration of complete sets of low-voltage distribution system, complete sets of low-voltage distribution system cabinet system in the crowded bus cable or distribution of electric energy to low voltage power distribution cabinet on each floor, redistribution to large UPS (500kVA, 600kVA), the current at the low voltage distribution system general maximum configuration to 2000kVA, each with a maximum of two sets of low voltage system of large capacity 1+ 1 type UPS or type 2N UPS system, the structure of high voltage power distribution systems - from low voltage power distribution system -UPS in the early application of small data center, but with the increase of data center power distribution capacity of single UPS system, many defects of this distribution structure.
First, the waste of investment is serious. A single low voltage distribution system is wasteful of investment, waste of space, and waste of dense busbar. Although it is possible to transformer configuration on each floor, but no changes in the structure of power supply, with the use of large UPS, under the low voltage distribution system of each 2000kVA 2 600kVA (1+1) considering the charging current and the load is full of redundancy.
Second, increase the level of power supply and distribution, and increase the hidden danger of security. In the same power supply device environment, for the distribution system, the less the upstream and downstream switches are, the safer. The less the distribution level is, the higher the reliability. The higher the voltage level near the load center, the more energy saving. Large data center park 35kV switchgear, -10kV high voltage switchgear, -10kV distribution cabinet, transformer low voltage switchboard, dense busbar floor switchboard -UPS system, 8 tier power distribution structure, every 1 or more levels means adding a hidden danger point.
Third, it will affect the available area of the machine room and increase the cost of the building. For large data center, if every floor of the configuration of low-voltage distribution transformer chamber, UPS system power supply room, corresponding power area should set aside more than 40% space for communication room, usually reserved for the 25%~30% space, and the greater the redundancy structure of low voltage power distribution room for a larger area.
Medium voltage integrated UPS is on the rise
Review the development trend of high and low voltage power distribution communication field, AC system from 10kV to early 380V, uninterrupted power supply from 220V to 240V, 336V high voltage DC voltage, the greater the degree of power equipment intensive distribution system also increased, the voltage level of the equipment can reduce the line loss, more investment, save equipment floor bus cable area, reduce the number of transitions also means the same, energy saving, change the traditional 380V into 380V structure 220V distribution, improve the UPS into the voltage level to above 10kV have more advantages. The premise of using UPS such as 10kV is to transfer the metering function, power compensation function and low voltage generator to 10kV system.
中興ZXDU58 W600 V4.5R01M01室外壁掛式電源柜
High voltage end metering can be used in the measurement of low voltage distribution. The traditional data center is usually configured through metering cabinet at low pressure in the low voltage distribution system, but with the increasing scale of data center, large data center has more than 10 sets of low-voltage distribution system, and divided into electricity, electricity and other office work, statistics on the pressure will become a trend. At the same time, the data acquisition of the medium voltage integrated UPS transformer can be collected and reported automatically by the high voltage end measurement.
The compensation function in low voltage distribution can be changed to high voltage compensation and load center close compensation. For data centers, there is also the inductive and capacitive loads, inductive load mainly for air conditioner, fan motor equipment; rectification equipment, IT equipment for the capacitive load; also said data center of the inductive and capacitive loads exist at the same time, is complement each other. Statistics show that at present, most of the low voltage capacitor cabinet of the communication bureau building is set up。
“模范城市曼海姆(MOMA)”項目是由德國政府啟動的“未來能源系統(tǒng)”計劃的一部分。該項目通過在當?shù)仉娋W(wǎng)中部署先進的信息通信技術(shù)以及小型裝置,使消費者直接體驗可再生電能的波動使用特點。
MOMA電網(wǎng)將來自超過500個生產(chǎn)商供應(yīng)的電力配送至曼海姆及毗鄰的德累斯頓市。電網(wǎng)本身兼作電力線寬帶系統(tǒng),連接了大量家用智能設(shè)備。該項目始于2010年,至今已有1000名居民參加,這些居民的家電都連接到這個“能源互聯(lián)網(wǎng)”中,并利用眾多的軟件工具監(jiān)控其電力使用和支出狀況。
MOMA首席執(zhí)行官英戈 勛伯格(Ingo Schoenberg)表示:“可再生能源最大的挑戰(zhàn)是,時而有風,時而陽光普照,但當你需要的時候它們并不一定可用。MOMA項目尋求供求平衡的方法,力求在高波動性的能源發(fā)電和智慧的能源消耗之間取得平衡,并同時提高效率。”
勛伯格說:“通過將稅費與電網(wǎng)容量相連接,鼓勵項目參與者在能源可用性高、價格低的時候用電。對于那些不愿意自己調(diào)節(jié)設(shè)置的用戶,MOMA甚至制定了‘節(jié)能管家’幫助用戶在能量充足、價格便宜的時段打開電器。項目的運行狀況表明,當消費者知悉能源的真實價格時,自然會改變使用方式。”
在知識和技術(shù)的武裝下,私人用戶節(jié)約了10%左右的能耗和15%的能源費用,而電力運營商能夠更好地管理網(wǎng)絡(luò)負載。MOMA項目的成果為制定彈性電價、建立同時承載智能電網(wǎng)和智能電表的單一通信平臺提供了立法的依據(jù)。
高品質(zhì)通信網(wǎng)絡(luò)助力電網(wǎng)升級
MOMA項目采用的技術(shù)解決方案也為電力供應(yīng)商提供了解決電力中斷并提高運營效率的新方法。在美國,風暴和“小動物”嚴重破壞電力供應(yīng),加州大學伯克利分校2004年的一項研究表明,美國每年由停電造成的損失達到800億美元。
田納西州的查塔努加電力委員會為分布在約1500平方公里的居民提供電力服務(wù)。根據(jù)伯克利大學的數(shù)據(jù)計算,每年停電會對其服務(wù)區(qū)域造成約1億美元的損失,但該電力委員會并不是一個典型的美國能源供應(yīng)商。
2012年,在美國能源部“復蘇法案”的11550萬美元的資金刺激下,查塔努加電力委員會完成了高度自動化的智能電網(wǎng)升級工作,為電網(wǎng)配備了智能傳感器、開關(guān)和儀表。與MOMA項目一樣,其電網(wǎng)以高品質(zhì)的通信網(wǎng)絡(luò)為基礎(chǔ),查塔努加電力委員會選擇了光纖寬帶網(wǎng)絡(luò)承載消費者三網(wǎng)合一的服務(wù)。
電力委員會執(zhí)行副總裁大衛(wèi) 韋德(David Wade)表示:“這應(yīng)該就是未來電網(wǎng)的樣子,美國還沒有其它公共事業(yè)能夠達到如此高的自動化水平。但是,一切都取決于通信能力,查塔努加的電網(wǎng)與光纖網(wǎng)絡(luò)無縫銜接,這使得查塔努加成為實現(xiàn)我們未來設(shè)想的最佳場所。”
現(xiàn)在,在查塔努加,如果一輛汽車撞到了電線桿,電力委員會的電網(wǎng)將會進行“自我修復”。電網(wǎng)中的1200個智能開關(guān)可以通過光纖網(wǎng)絡(luò)確定電路中斷的位置,并改道供電。2月12日,查塔努加遭遇了20年來最嚴重的暴風雪,4萬名居民的供電自動恢復,其他3.6萬名居民的供電在工程師的幫助下,3天之內(nèi)恢復正常。
中興ZXDU58 W600 V4.5R01M01室外壁掛式電源柜
電力委員會估計,以前恢復這7.6萬名居民的供電需要8天的時間。2012年以來,該區(qū)域的斷電事件減少了50%~60%,每年為當?shù)販p少了5000萬美元的支出。電力委員會自身也大大節(jié)約了成本:在維修、資產(chǎn)管理、上門服務(wù)以及盜竊方面,節(jié)約的成本高達1050萬美元。
自動化解決方案創(chuàng)建更加智能的電網(wǎng)
最終用戶的偷電行為仍然讓電力供應(yīng)商頭疼不已,嚴重影響了利潤的獲取。華為,一家來自中國的技術(shù)公司,針對電力供應(yīng)面對的新挑戰(zhàn)設(shè)計了不同的解決方案,既包括大規(guī)模的網(wǎng)絡(luò)基礎(chǔ)設(shè)施項目,也包括專門處理偷電等局部問題的核心平臺。
據(jù)華為介紹,尼日利亞的消費者偷電狀況尤其嚴重,供電商一直無法找出問題的原因,到目前為止,無法收集到準確的能耗數(shù)據(jù)的用戶數(shù)量超過了80%。
為了解決這個問題,華為正準備在尼日利亞安裝一個覆蓋40萬本地家庭的自動抄表系統(tǒng),支持高速數(shù)據(jù)連接,同時部署新的傳感器和控制器。該系統(tǒng)部署完成后,客戶的電表將每15分鐘傳輸一次數(shù)據(jù)到當?shù)剡\營商,從而使運營商獲得實時的用電數(shù)據(jù)。
華為企業(yè)BG Marketing與解決方案銷售部總裁何達炳說:“該系統(tǒng)將有效提高電力公司的營業(yè)額和利潤。即時通信系統(tǒng)和可靠的電力基礎(chǔ)設(shè)施維護是電力高效生產(chǎn)和配送的關(guān)鍵。其可以實現(xiàn)早期預(yù)警、實時故障定位、自我修復和有效負載管理等功能。”
隨著中國經(jīng)濟的崛起,城市的蓬勃發(fā)展給傳統(tǒng)電網(wǎng)帶來了極大壓力。珠海電力局要為珠海市、淇澳島、橫琴島和高欄島的822萬居民供電。面對著各種接入、可靠性、成本和容量問題,傳統(tǒng)的固定和無線技術(shù)已經(jīng)無法滿足業(yè)務(wù)要求,珠海電力局迫切需要提高網(wǎng)絡(luò)的自動化水平。
對于珠海電力局而言,在其服務(wù)區(qū)域安裝光纖電纜過于昂貴復雜。因此,其選擇了成本相對較低、但速度與光纖相似的華為4G LTE無線集群系統(tǒng)。與傳統(tǒng)雙向無線通信系統(tǒng)一樣,華為eLTE無線集群解決方案為珠海電力局提供了專用無線網(wǎng)絡(luò),從而實現(xiàn)配電自動化通信。
同樣,在中國東部沿海城市青島,華為改造了阻礙電力性能的老舊線路和不可靠的通信網(wǎng)絡(luò)。華為全光xPON解決方案具備高度自動化的特點,幫助青島供電公司有效管理分布式供電,并提高網(wǎng)絡(luò)可靠性。
華為表示,通過利用網(wǎng)絡(luò)中的智能終端對數(shù)據(jù)進行實時監(jiān)測,在數(shù)秒之內(nèi),就可以隔離故障線路,實現(xiàn)電網(wǎng)的自動修復。現(xiàn)在,青島供電公司每年停電時長減少了2.6小時,達到每戶1.1小時;每年電力損失下降了33.4兆千瓦時。
總而言之,為建立環(huán)境友好型社會,公用事業(yè)單位面臨著降低成本、優(yōu)化運營以及遵守更加嚴格的規(guī)定等方面的壓力。為應(yīng)對這些挑戰(zhàn),華為等科技公司提供大量解決方案,從而創(chuàng)建更加智能的電網(wǎng),最終提供更加環(huán)保的能源。
The "model city of Mannheim (MOMA) project by the German government launched the" future energy system is a part of the project ". By deploying advanced information and communication technology and small devices in the local power grid, the project directly enables consumers to experience the fluctuating characteristics of renewable energy.
MOMA grid will be from more than 500 manufacturers of power supply and distribution to the adjoining Dresden city of mannheim. The power grid itself is also a power line broadband system, which connects a large number of household intelligent equipment. The project began in 2010. Up to now, 1000 residents have participated. The household appliances are connected to the "energy Internet", and many software tools are used to monitor their electricity use and expenditure.中興ZXDU58 W600 V4.5R01M01室外壁掛式電源柜
Schoenberg, chief executive of MOMA, Ingo Schoenberg, said: "the biggest challenge of renewable energy is that sometimes it is windy and sunny. But when you need it, they are not always available. The MOMA project seeks a balanced supply and demand approach to achieve a balance between high volatility energy generation and intelligent energy consumption, and increase efficiency. "
"By connecting tax and electricity to power grid capacity," Schoenberg said, "project participants are encouraged to use electricity when they have high energy availability and low prices. For users who don't want to adjust their settings, MOMA even set up an energy-saving housekeeper to help users turn on electrical appliances at the time of energy sufficiency and cheap price. The operation of the project shows that when the consumer knows the real price of the energy, it will naturally change the way of use. "
Under the arming of knowledge and technology, private users save about 10% of energy consumption and 15% of energy costs, while electric power providers can better manage network load. The results of the MOMA project provide a legislative basis for the establishment of elastic electricity price, the establishment of a single communication platform carrying smart grid and intelligent electric meter.
High quality communication network upgrade power grid upgrading
The technical solutions adopted by the MOMA project also provide a new way for power suppliers to resolve power interruptions and improve operational efficiency. In the United States, storms and small animals seriously disrupt the power supply. A 2004 study by University of California at Berkeley showed that the annual loss caused by power cuts in the United States amounted to 80 billion dollars.
The Char Thanou Fagafaga Electric Power Commission in Tennessee provides electricity for residents of about 1500 square kilometers. According to the data from Berkeley University, the annual blackouts will cause about 100 million US dollars loss to the service area, but the Electric Power Commission is not a typical US energy supplier.
In 2012, under the stimulus of the US $115 million 500 thousand recovery program of the energy department, the Char Thanou Fagafaga Electric Power Commission completed highly automated upgrading of smart grid, which equipped smart sensors, switches and meters for the power grid. Like MOMA project, its power grid is based on high quality communication network. Char Thanou Fagafaga Electric Power Commission has chosen optical broadband network to load consumers' three networks in one service.
David Wade, executive vice president of the Electric Power Commission, said: "this should be the way of the future grid. No other utilities in the US can achieve such high automation level in the future." Wade said. But everything depends on communication capability. Char Thanou Fagafaga's power grid and optical fiber network seamlessly connect, which makes Char Thanou Fagafaga the best place to achieve our future vision.
Now, in Char Thanou Fagafaga, if a car hits a pole, the power Com中興ZXDU58 W600 V4.5R01M01室外壁掛式電源柜mittee's power grid will be "self repairing". 1200 smart switches in the power grid can determine the location of the interruption by the optical fiber network and switch to the power supply. In February 12th, Char Thanou Fagafaga suffered the most severe snowstorm in 20 years. The power supply of 40 thousand residents recovered automatically, and the power of 36 thousand other residents was restored to normal within 3 days with the help of engineers.
The Power Commission estimates that the restoration of electricity from the 76 thousand residents will take 8 days. Since 2012, power outages in the region have been reduced by 50%~60% and $50 million a year for local expenditure. The Power Commission itself has also greatly saved costs: the cost of saving up to $10 million 500 thousand in maintenance, asset management, door-to-door services and theft.
Automated solutions create more intelligent power grids
The end user's electricity theft still makes the power suppliers headache, seriously affecting the gain of profits. HUAWEI, a technology company from China, designed different solutions for the new challenges faced by the power supply, including large-scale network infrastructure projects, including the core platform for dealing with local issues such as stealing electricity.
According to HUAWEI, the situation of consumers stealing electricity in Nigeria is particularly serious. Power providers have been unable to find out the cause of the problem. Up to now, the number of users who can not collect accurate energy consumption data has exceeded 80%.
To solve this problem, HUAWEI is preparing to install an automatic meter reading system covering 400 thousand local families in Nigeria, which supports high-speed data connection, and deploys new sensors and controllers at the same time. After the system is deployed, the customer's meter will transmit data every 15 minutes to the local operator, enabling the operator to obtain real-time data on electricity.中興ZXDU58 W600 V4.5R01M01室外壁掛式電源柜
"The system will effectively improve the turnover and profit of the power company," said He Dabing, President of HUAWEI BG Marketing and the Sales Department of the solution. The key to efficient power production and distribution is the instant communication system and the reliable maintenance of the power infrastructure. It can realize early warning, real-time fault location, self repair and effective load 中興ZXDU58 W600 V4.5R01M01室外壁掛式電源柜
中興ZXDU58 W600 V4.5R01M01室外壁掛式電源柜
ACS600產(chǎn)品家族按應(yīng)用可分為以下五種專用系列:ACS 600:可滿足絕大多數(shù)應(yīng)用要求。ACC 600:專用于位勢負載應(yīng)用。例如起重機,提升機,電梯等等。ACP 600:專用于對轉(zhuǎn)角,位移做精確控制。ACA 600:專用于系統(tǒng)傳動。 ACS 600的重要特性及功能如下˙無與倫比的電機速度及轉(zhuǎn)矩控制。˙電機辨識運行(ID RUN)及速度自我微調(diào)功能。˙內(nèi)置 PID控制器,降低了您的投資成本。˙工具軟件對傳動的支持: Drives Size選型軟件,Drives Builder工程設(shè)計軟件,Drives Window傳動調(diào)試軟件, Drives Link利用Windows監(jiān)視傳動,Drives Support服務(wù)專家。˙ACS600SingleDrive能在幾毫秒內(nèi)測出電機的實際轉(zhuǎn)速和狀態(tài),所以在任何狀態(tài)下都能立即起動,無起動延時。˙零轉(zhuǎn)速下,不需速度反饋就能提供電機滿轉(zhuǎn)矩。˙ACS600SingleDrive能夠提供可控且平穩(wěn)的最大起動轉(zhuǎn)矩。可達到200%的額定轉(zhuǎn)矩。˙不需特殊硬件的磁通制動模式可以提供最大的制動力矩。˙在磁通優(yōu)化模式下,電機磁通自動適應(yīng)于不同的負載以提率同時降低電機的噪音,變頻器和電機的總效率可提高 1%-10%。˙具有標量控制(SCALAR CONTROL)和IR補償功能。
型號 | 工作面寬度(mm) | 刀轉(zhuǎn)速(r/min) | 重量(kg) | 功率(kw) | 尺寸(mm) |
HQZ600 | 600 | 150 | 130 | 3 | 600×400×800 |
產(chǎn)品簡介
SF6氣體作為目前發(fā)現(xiàn)的最穩(wěn)定的溫室效應(yīng)氣體,踞實驗證明在10.5um處具有強烈的光譜吸收特性。SF6激光變送器利用二氧化碳激光器、窄帶濾光片、高靈敏低噪聲光電探測電路、穩(wěn)定的光斬波器、參考光路和開放式光路結(jié)構(gòu)等先進的設(shè)計方法和技術(shù)實現(xiàn)了對待測區(qū)域中SF6氣體濃度的實時、在線、開放式高靈敏紅外激光光譜遙測。
SF6激光變送器是在分析和比較國內(nèi)外同行業(yè)相關(guān)氣體檢測方法的基礎(chǔ)上,將先進的開放式光路高靈敏中紅外激光吸收光譜技術(shù)應(yīng)用于SF6氣體檢測,完全擁有自主知識產(chǎn)權(quán),國內(nèi)首創(chuàng),技術(shù)水平達到國際領(lǐng)先。智能SF6激光變送器克服了傳統(tǒng)的SF6檢測儀必須進行采樣,從而只能實現(xiàn)點式測量的弱點,采用開放式光路,不需要采樣就能測量區(qū)域中SF6氣體的濃度;集氣體分析、模擬量輸入、開關(guān)量輸入、協(xié)議轉(zhuǎn)換、通信接口轉(zhuǎn)換、傳輸和開關(guān)量輸出控制等功能于一體,覆蓋了工業(yè)控制及監(jiān)測系統(tǒng)的現(xiàn)場采集所需功能,能根據(jù)各種應(yīng)用場合的具體要求進行靈活配置的智能型采集系統(tǒng)。
智能SF6激光變送器綜合運用了開放式光路高靈敏中紅外激光吸收光譜技術(shù)、數(shù)據(jù)采集處理、通信技術(shù)于一體的開放系統(tǒng)平臺,它的所有功能均采用模塊化設(shè)計,便于工程安裝及工程維護。系統(tǒng)自身帶有自動濃度校準功能,不需要額外的定期校準。
功能特點
★.激光變送器由智能模擬量采集器、激光發(fā)射與光強監(jiān)測單元、激光接收單元、信號處理單元等組成,達到實時監(jiān)測區(qū)域空氣中SF6氣體濃度的目的。智能SF6激光變送器功能說明:
★.對區(qū)域空氣中SF6氣體的定量檢測分析功能(運用開放式光路高靈敏中紅外激光吸收光譜技術(shù),消除了激光自身強度波動和外界環(huán)境的影響)。
★.實時顯示區(qū)域空氣中的SF6氣體濃度值,任意設(shè)置報警濃度,當環(huán)境中SF6氣體濃度超過設(shè)定的報警值時發(fā)出超標報警功能。
★.每一個SF6氣體激光探測器可監(jiān)測0.1~200m范圍內(nèi)的SF6濃度變化,不需要任何采樣裝置,只需要一個反射器,激光經(jīng)過要監(jiān)測的區(qū)域后被反射器反射回來到達探測器,就實現(xiàn)了對整個光路中的SF6濃度的測量。
★.利用激光光譜吸收技術(shù)檢測,對SF6氣體泄露檢測,測量精度可高于百萬分之一,檢測分辨率達到1ppm量級,而且重復性好,穩(wěn)定可靠,使用壽命長,定量分析,采用開放式光路技術(shù),避免了采樣而且實現(xiàn)了大范圍的連續(xù)空間的監(jiān)測,操作簡單,故障率少。
技術(shù)參數(shù)
★ SF6濃度檢測范圍:0~2000ppm,誤差小于10ppm
SF6濃度檢測最小示值:1ppm
★ 泄漏報警閥值: 1000ppm 或 可調(diào)
★ 報警誤差:<5%
★ 氧氣濃度檢測范圍:0~25.0%
氧氣濃度檢測誤差:<0.5%
氧氣濃度檢測最小示值:0.1%
★ 缺氧報警閥值:18.0% 或 可調(diào)
★ 溫度檢測范圍:-30~100℃
★ 相對濕度檢測范圍:0~100%
★ 檢測點:標準配置12點(可擴展到36點)。
★ 數(shù)據(jù)記錄功能:報警事件自動記錄,海量存儲,自動更新。
★ 報警輸出:繼電器空接點輸出,可與RTU相連,同時支持RS485報警輸出。
★ 支持RTU遠程啟動風機功能。
★ 支持紅外人體檢測,自動啟動風機或語音提示。
★ 風機控制器:開關(guān)型:直接控制風機電源;脈沖型:與風機控制開關(guān)相連。
可根據(jù)現(xiàn)場情況選配。
★ 風機啟動支持多種模式:定時啟動、報警啟動、有人時自動啟動、遠程啟
動、手動啟動等。
★ 主機多種形式:壁掛式、3U 19英寸標準機箱、觸摸屏落地POS機式;仿
windows界面,用戶界面友好。
★ 通過RS485支持測量數(shù)據(jù)遠傳輸出如:門口安裝大型LED顯示屏,遠處立即看
到測量參數(shù)和系統(tǒng)運行情況。 (需用戶另行選配)
RBK-6000天然氣報警器是濟南聚乾電子有限公司生產(chǎn)的一款經(jīng)濟實用的個人用氣體泄漏檢測儀,高性能鋰電池和傳感器機器連續(xù)工作。性能,使用方便,堅固耐用。采用堅固的工程塑料外殼,能承受使用現(xiàn)場可能發(fā)生的跌落碰撞,結(jié)構(gòu)緊湊、輕便,可以很容易的夾在口袋、皮帶或者安全帽上。RBK-6000天然氣報警器主要用于檢測危險環(huán)境中的可燃、有毒有害氣體,即使在極其苛刻的條件下也能提供數(shù)字化的氣體濃度值,高、低濃度報警值和低電量報警,另外若當前氣體濃度超過量程,RBK-6000天然氣報警器將會以聲、光和振動報警提醒用戶,為您提供連續(xù)的安全。檢測探頭技術(shù)、性能、穩(wěn)定性高、具有通訊和自診斷功能、安裝維護方便。的避免因可燃氣體泄漏而引起的火災(zāi)、爆炸、中毒等人身傷亡事故和財產(chǎn)損失,是安全生產(chǎn)的必備儀器。RBK-6000天然氣報警器特點:
產(chǎn)品特點: ◆ 使用高速cpu處理器,能夠快速精確地處理系統(tǒng)任務(wù),系統(tǒng)的性;◆ 采用高精度氣體傳感器,性強;◆ 快速預(yù)熱,相應(yīng)時間迅速;◆ 友情語音提示。
技術(shù)參數(shù): ◆ 檢測原理:催化燃燒式進口傳感器◆ 檢測氣體:可燃氣體◆ 采樣方式:自然擴散式◆ 測量精度:±5%FS◆ 相應(yīng)時間:≤30s◆ 工作電壓:AC220V±10%◆ 溫 度: 0℃~55℃◆ 濕 度:≤95%RH◆ 報警系統(tǒng):聲光報警◆ 報警音量:≥75dB體 積:113mm(L)×80mm(W)×39mm(H)